Lab 101-C — Filament Temperature from a Light Bulb
Goes with: Unit 5. Time: 2 hours. Cost: about \(50–\)100 (estimate; the bench supply is reused in many later labs).
Goal
Measure a small incandescent bulb's voltage and current from glowing dull red to full brightness, use the resistance–temperature behaviour of tungsten to estimate the filament temperature, and connect colour and power to Planck's and Stefan–Boltzmann's laws.
What you will learn
- Ohm's law and non-linear (temperature-dependent) resistance.
- Estimating temperature from a material property.
- Stefan–Boltzmann scaling (\(P \propto T^4\)) and Wien's shift of colour with temperature.
Shopping list
| Item | Spec / example | Qty | Approx. cost (estimate) | Where |
|---|---|---|---|---|
| Adjustable DC bench power supply | 0–30 V, 0–5 A with V and A displays (e.g., Korad KA3005D or Eventek KPS305D class) | 1 | $50–90 | Amazon |
| Small incandescent bulbs | automotive #194 (≈ 14 V, 0.27 A) and/or #1156 (≈ 12.8 V, ~2 A) with sockets/pigtails | 3–4 | $5–10 | auto-parts store, Amazon |
| Second multimeter | to measure current and voltage independently of the supply's displays | 1 | $20–30 | Amazon |
| Leads with alligator clips | — | 1 set | $8 | Amazon |
| Thermometer (room temperature) | any | 1 | — | household |
| Optional lux meter | — | 1 | $20–30 | Amazon |
Safety
- Bulbs get hot (a #1156 can burn skin within seconds) — use a socket on a non-flammable surface.
- Do not exceed the bulb's rated voltage by more than ~10 %; filament failure is sudden and the glass can crack.
- Low voltage (< 15 V) — no shock hazard; avoid shorting the supply outputs.
Background: resistance as a thermometer
Tungsten's resistivity rises roughly 15-fold from room temperature to ~3000 K. Tabulated data (CRC Handbook) are well approximated, for this lab, by
This fit is our approximation (good to roughly ±10 % in temperature over 300–3000 K). For better accuracy, interpolate directly in the CRC resistivity table.
Procedure
- Cold resistance. Measure \(R_\text{cold}\) with the multimeter's ohm range (subtract lead resistance by touching leads together). Better: use the supply at a tiny current (e.g., 10 mA) where the filament does not warm: \(R = V/I\). Record room temperature \(T_0\); correct to 300 K if needed.
- Connect the supply in constant-voltage mode with the second meter in series (current). Increase voltage in steps: 0.1, 0.2, 0.5, 1, 2, 3 … up to rated voltage.
- At each step wait 10 s, record \(V\), \(I\), colour seen (none / dull red / orange / yellow / white), and optional lux.
- Repeat for a second bulb type.
Analysis
- Compute \(R = V/I\) and \(P = VI\) for each step.
- Estimate \(T\) from \(R/R_{300}\).
- Plot \(\log P\) against \(\log T\). Radiation dominates at high temperature, so the slope should approach 4 (Stefan–Boltzmann). At low temperatures conduction through the leads and gas cooling lower the slope.
- Compute the Wien peak \(\lambda_\text{max} = 2.898\times10^{-3}/T\) at full voltage and plot the Planck curve for that temperature against the visible band (Unit 5 code).
- Compare the colour you saw with the Planck curve: first visible glow is dull red around ~800–900 K (Draper point ≈ 798 K).
Expected results
- \(R_\text{hot}/R_\text{cold}\) of roughly 10–15 at rated voltage → \(T \approx\) 2300–2900 K for small automotive bulbs (estimate).
- The I–V curve is strongly non-linear (not a straight line through the origin).
- \(\log P\) vs \(\log T\) slope rising toward ~3.5–4 at the highest temperatures.
- Wien peak around 1.0–1.3 µm: most output is infrared; the bulb is a heater that happens to glow.
How to interpret
The experiment shows directly that thermal emission is mostly IR at filament temperatures, explaining why halogen lamps are poor solar simulators and why the ~5800 K Sun is so much bluer. The \(T^4\) law is why a modest temperature increase in a furnace or on the Sun's surface changes emitted power dramatically — and why radiative heat transfer dominates in crystal-growth hot zones (SOL 301).
Sources
- CRC Handbook of Chemistry and Physics, "Electrical resistivity of pure metals" (tungsten vs T). Power-law fit is our approximation.
- Draper point: standard value (~798 K).
- PVEducation "Blackbody Radiation".